Boric Acid Filtration Plant — Vacuum Belt Filter Modernization

Active surface area: 60 m² | Process: Hot filtration

Project overview

The vacuum belt filter modernisation at the boric acid filtration plant covers a filter unit with a 60 m² active filtration area, configured for a hot filtration process. Hot filtration is the mode of operation in which the solution is fed to the filtration step without being cooled. The work covered process design, equipment fabrication, site piping, electrical and automation integration and commissioning, all delivered by Miyay Process.

The filter equipment was produced by laser cutting, stainless welding and precision machining, and the control side was built with PLC and SCADA integration. The unit was installed at Eti Maden's boric acid filtration plant in Kütahya in 2018.

01

Setting out the hot filtration scope

The hot-solution duty of the existing filtration line and the site conditions were reviewed, and the process design scope of the modernisation was set out.

02

Sizing for 60 m² active area

The filter was sized on a 60 m² active filtration area and a hot filtration process.

03

Fabrication and line connection

The filter equipment was fabricated through laser cutting, stainless welding and precision machining, and the site installation and piping work were completed.

04

Commissioning the hot line

After electrical and automation integration, commissioning was carried out and the unit was put into service on the hot filtration line.