Boric Acid Filtration Plant — Vacuum Belt Filter Modernization 2

Active surface area: 27 m² | Vacuum: -0.8 bar

Project overview

The modernisation of the vacuum belt filter at the boric acid filtration plant replaces the existing filtration step with a new belt filter rated for a 27 m² active filtration area and a -0.8 bar vacuum value. Vacuum belt filters are used to dewater the solids separated from the solution continuously on a moving belt and discharge them. Miyay Process replaced the existing filtration step and handled process design, equipment fabrication, site piping, electrical and automation integration and commissioning.

Fabrication scope covers laser cutting, stainless welding and precision machining; the electrical and automation side was integrated through PLC and SCADA. The modernisation was carried out at Eti Maden's boric acid filtration plant in Kütahya in 2019.

01

Reviewing the existing filtration step

The process design scope of the modernisation was defined around the existing vacuum belt filter at the plant and its site connection points.

02

27 m² active area arrangement

The new filter was sized on a 27 m² active filtration area and a -0.8 bar vacuum value.

03

Filter fabrication and site installation

The filter equipment was fabricated through laser cutting, stainless welding and precision machining and installed on site, with piping connections made in place.

04

Commissioning the modernised filter

After electrical and automation integration, commissioning was completed and the modernised filter was taken into the line.